Installation Manual
Installation Diagrams

The
Ecoplus PRT can be installed anywhere in the house provided that it allows
easy access to the required pipes.
In most cases, it is installed in the
boiler-house or the airing cupboard. As the unit may become hot, the best
position for the PRT is on the floor or resting on a flat surface. The
exact location of the unit will vary depending on the configuration of the
central heating system in which it is being installed.
The diagrams in the following pages
show some of the possible central heating system configurations and are
designed to help you during installation.
If you are installing Ecoplus PRT in a
central heating system with a configuration that is not indicated in this
manual and require clarification or if you require further information,
please contact Ecoplus Limited; Tel: +353667190350 , Fax: +353667190357,
e-mail:
support@ecoplusprt.com.
To download a PDF
version of the latest Installation Manual, click here
or scroll to the bottom of the page.
Click on the appropriate scenario to see the
diagram:
|
|
|
|
|
|
|
|
|
|
|
|
the
diagrams below are not to scale |
Scenario 1 - Combi Boiler Installation

Back to top
Scenario 2 - Single-Boiler heating system with
one, or two zones

|
Note
 |
The Primary Pump
should be set at its lowest setting (normally 1).
Zone 1 and 2 should be electrically wired independently.
The Primary Pump
should be wired so that it starts with the burner. |
Scenario 3 - Flow and return at high levels
for the radiators through the attic.
This is a typical installation in
cases where the heating system was installed after the house was built.

Back to top
Scenario 4 - Flow and return at high levels to
feed the copper cylinder.

|
Note
 |
The Auto vent is placed on the
pipe connected above the PRT (port 1) to exhaust the gases. If the
Auto Vent was not put there, the gases could not vent out the
expansion pipe.
To prevent gravity flow from
cylinder when the system shuts down, place a non-return valve on the
primary line. |
Scenario 5 - Sealed system - flow and return
taken at high levels (through an attic).

|
Note
 |
To prevent gravity flow from cylinder when the system
shuts down, place a non-return valve on the primary line. |
Scenario 6 – Flow and Return taken at high
level for the radiators

Back
to top
Latest
Installation Manual
|
To view the
manual, you need to have Adobe® Acrobat® installed on your computer.
You can download Adobe Acrobat from the Adobe Website. |
 |
| You can download
the latest version of the instruction manual in Adobe® PDF Format by
clicking the link below.

Download the latest
Installation Manual (336 KB)
|
 |